Mitsubishi Electronics C64 Crib Toy User Manual


 
7. Servo Parameters
7.4 Supplement
172
7.4.2 Electronic Gears
The servo drive unit has internal electronic gears. The command value from the NC is converted into a
detector resolution unit to carry out position control. The electronic gears are single gear ratios
calculated from multiple parameters as shown below. However, each value (ELG1, ELG2) must be less
than 32767.
If the value overflows, the initial parameter error (alarm 37) or error parameter No. 2301 will be output.
If an alarm occurs, the mechanical specifications and electrical specifications must be revised so that
the electronic gears are within the specifications range.
<Semi-closed loop>
ELG1 RNG1 x PC2
ELG2
=
PIT x PC1 x IUNIT
(Reduced fraction)
<Closed loop>
ELG1 PGN x RNG2 x PC2
ELG2
=
30 x RNG1 x PC1
(Reduced fraction)
IUNIT = 2/NC command unit (µm)
1µm : IUNIT = 2, 0.1µm : IUNIT = 20
When the above is calculated, the following conditions must be satisfied.
ELG1 32767
ELG2 32767