Honeywell MKXXII Crib Toy User Manual


 
Honeywell
MK XXII EGPWS Installation Manual
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C
SHEET
65
3.3.2.6 Shadin 2000 (Cat. 2 ID 10)
Air Data Type 10 (Shadin 2000 or equivalent) is a low speed, digital ARINC 429 signal having the
air data labels 203, 204, 206, and 212. Total Air Temperature is from a dedicated (EGPWS) 500-
ohm probe using +5 volt excitation from the MK XXII EGPWC.
39
38
A
B
J2
ARINC 429 Air Data
ARINC 429 Bus - Hi
ARINC 429 Bus - Lo
EGPWS MK XXII
A
B
ARINC 429 Low Speed
Air Data Bus
(+)
(-)
Temp. Input
Chassis Ground
+5V Excitation
500 ohm
Temperature
Probe
25
63
44
53
J1
Shadin2000.vsd
Cat 2 Bus 1 Bus 2
Vendor PN ID A B A B
962830-1,2,3 10 J2-7 J2-8
962830A-1,2,3
962830A-X-S-4
962830A-X-S-5
962830A-1-S-7(B212/412)
10
J1-40 J1-22
NOTE: The connector pin numbers given in the Table above are to the best knowledge of Honeywell EGPWS
engineering. Please contact the manufacturer’s customer service to confirm your installation.