Table E3.1.6-236 Display Configuration (Collins ProLine IV, 5x6)
Function Value
Display Type Collins ProLine IV (5x6)
Sweep Type Standard with +/-60 degree limit
Category 7, Options Select Group #1
TA&D Alternate Pop Up: False TA&D Alternate Pop Up: True
Auto Pop Up
No Effect
Pop Up Controlled by Display
No Effect
Pop Up Controlled by Display
Category 7, Options Select Group #1
Peaks Enabled: False Peaks Enabled: True
Peaks Mode
(Available as of -011)
Peaks Off Peaks On
Pop Down Never Automatically pop down
Manual select Anytime
Manual deselect Anytime
Auto Range No
Moving Marker No
Overlay Page Yes; “TERR” is located on the right side of display.
“TERR” and Peaks Elevations located on upper left side of Terrain
image as of -011.
Display Priority Standard
Display bus type Standard ARINC 708
Terrain Mode Annunciation Standard
TERRAIN DISPLAY BUS #1
453TX_1
CONNECT TO:
A = J1-58
B = J1-59
Terrain Display data to switching relay/Symbol Generator
TERRAIN DISPLAY BUS #2
453TX_2
CONNECT TO:
A = J1-56
B = J1-57
Terrain Display data to switching relay/Symbol Generator
Display Input Control
CHANNEL
429_422RX_1
CONNECT TO:
IOC #1 Bus (High Speed)
Format: ARINC429
Fault Designation: IOC BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Range (Mode/Range Word)
Label
155
Sig. Bits
Discrete
Range
5-640NM
Signal Type
Basic
Resolution
N/A
Rate (ms)
50
CHANNEL
429RX_3
CONNECT TO:
IOC #2 Bus (High Speed)
Format: ARINC429
Fault Designation: IOC BUS 2
BUS TYPE: BASIC
A = J2-41
B = J2-40
Data
Range (Mode/Range Word)
Label
155
Sig. Bits
Discrete
Range
5-640NM
Signal Type
Basic
Resolution
N/A
Rate (ms)
50