Honeywell MKXXII Crib Toy User Manual


 
Honeywell
MK XXII EGPWS Installation Manual
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C
SHEET
61
not detect autorotation and thus do not provide the autorotation altitude callouts or advanced gear
warnings. Mode 1 is inhibited in these types. The generic types are segregated into retractable
and fixed gear configurations and tail strike warning profiles. Contact the Honeywell GPWS hot
line 1 800 813-2099 for help in selecting the correct generic type.
Category 1 ID types 150, 151, 152 and 153 are provided for applications where low level DC
torque signals are externally amplified and scaled to a common 0.040 VDC per %.
Category 1 ID types 154, 155, 156 and 157 are provided for applications where low level DC
torque is scaled and converted to ARINC 429 using the Shadin DC Torque to 429 Converter, Part
Number 933755-00. This is particularly applicable to S-76-A/A+/A++ /C, and Bell 407 aircraft.
Contact the Honeywell GPWS hot line 1 800 813-2099 for help in selecting the correct generic
type.
3.3.2 Category 2 – Air Data Input Select
Category 2 defines the Air Data interface. The Air Data input currently defines 5 analog and 6
digital air data types.
3.3.2.1 Instructions
1. Using Appendix E Table E 3, under Step/category 2 select Air Data Source. Using table E
3.1.2 and 3.1.2-x select the ID number for your air data source and record that number on
Table E 3 under Ident No. for step 2. This number will be used during programming of the
configuration module.
2. Using Appendix E Tables E 3.1.2-x, where x is the Air Data Type number, define the
electrical interfaces required to support your Air Data Type. Using Table E 3.1.2-x determine
the wiring interconnects and record it on Appendix A Fig A1-2.