Honeywell MKXXII Crib Toy User Manual


 
Honeywell
MK XXII EGPWS Installation Manual
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C
SHEET
187
TABLE E 3.1.1-8
TORQUE DATA SELECT 8 (AS365 DAUPHIN N3)
CHANNEL
RX429-8
CONNECT TO:
Eng #1 (low speed)
Fault Designation: ENGINE 1 BUS
Bus Type: Basic
A = J2-24
B = J2-07
Data
Torque
Label
211
Sig. Bits
15
Range
799%
Signal Type
Basic
Resolution
0.1
Rate (ms)
100
CHANNEL
RX429-5
(Note 1)
CONNECT TO:
Eng #2 (low speed)
Fault Designation: ENGINE 2 BUS
Bus Type: Basic
A = J2-21
B = J2-04
Data
Torque
Label
211
Sig. Bits
15
Range
799%
Signal Type
Basic
Resolution
0.1
Rate (ms)
100
Note 1: Digital Radar Altitude (type 2) can not be used with this configuration.
TABLE E 3.1.1-9
TORQUE DATA SELECT 9 (BELL 430)
CHANNEL
RX429-8
CONNECT TO:
Eng #1 (low speed)
Fault Designation: ENGINE 1 BUS
Bus Type: Basic
A = J2-24
B = J2-07
Data
Torque
Label
050
Sig. Bits
15
Range
0 to +126
Signal Type
Basic
Resolution
0.1
Rate (ms)
100
CHANNEL
RX429-5
(Note 1)
CONNECT TO:
Eng #2 (low speed)
Fault Designation: ENGINE 2 BUS
Bus Type: Basic
A = J2-21
B = J2-04
Data
Torque
Label
050
Sig. Bits
15
Range
0 to +126
Signal Type
Basic
Resolution
0.1
Rate (ms)
100
Note 1: Digital Radar Altitude (type 2) can not be used with this configuration.
TABLE E 3.1.1-10
TORQUE DATA SELECT 10 (BELL 407)
SIGNAL CONNECTION SUMMARY DATA
Engine Torque #1 (+) = J1-26
(-) = J1-27
Format: DC
Input Type: Basic
Fault Designation: ENGINE TORQUE 1
Validity: none
Engine Torque #2 (+) = J1-66
(-) = J1-47
Format: DC
Input Type: Basic
Fault Designation: ENGINE TORQUE 2
Validity: none
TABLE E 3.1.1-11
TORQUE DATA SELECT 11 (BELL 212/412)
SIGNAL CONNECTION SUMMARY DATA
Engine Torque #1 (+) = J1-26
(-) = J1-27
Format: DC
Input Type: Basic
Fault Designation: ENGINE TORQUE 1
Validity: none
Engine Torque #2 (+) = J1-66
(-) = J1-47
Format: DC
Input Type: Basic
Fault Designation: ENGINE TORQUE 2
Validity: none