E 5.3.2 CATEGORY 2, AIR DATA INPUT SELECT
The following table provides identification of the Air Data source type. The entry in the Air Data Type corresponds to a
table that provides detailed information on the configuration. For example, the details for Air Data Type #2 are found in
Table E 3.1.2. In this category, only the following signals are defined:
•
Uncorrected Barometric Altitude in analog and/or RS-422 or ARINC 429 format, and associated validity.
•
Temperature (Outside Air or Static Air) in analog or ARINC 429 format.
•
Corrected Barometric Altitude in ARINC 429 format.
•
Barometric Rate in ARINC 429 format.
•
Computed Airspeed in ARINC 429 format.
TABLE E 3.1.2: AIR DATA INPUT SELECT FOR EGPWS MKXXII
ID
Air Data Type
Description Effectivity
(Table E 3.1.2-x) App. Cfg.
00
Analog - altitude and 500
Ω
OAT (i.e., CIC
04077)
-001 -001
1 1 Digital – ARINC 429 (i.e., Bendix KDC 281) -001 -001
2 2 Digital – ARINC 575 (i.e., Collins ADC-80,
81, 82)
-001 -001
33
Analog - altitude and 500
Ω
OAT (i.e., Collins
ADS-65)
-001 -001
44
Analog - altitude and 500
Ω
OAT (i.e., CIC
02702)
-001 -001
5 5 Digital – ARINC 429 with Corrected Altitude
label 204
(i.e., Bendix KDC 481T)
-001 -001
6 6 Digital – ARINC 429 without Baro Rate label
212
(i.e., Honeywell AZ-810)
-001 -001
10 10
Digital – ARINC 429 and 500
Ω
OAT (i.e.
Shadin 2000)
-003 -003
11 11
Analog – altitude and 500
Ω
OAT (i.e.,
Honeywell AZ-241 or AZ-800 with additional
OAT). (Note 1)
-004 -004
12 12 Analog – altitude and internal constant for
OAT (i.e., Honeywell AZ-800 or AZ-241).
(Note 1)
-006 -006
Note 1: The AZ-800 provides an OAT signal with reference provided by the ADC. This is not compatible with the EGPWS
interface. The AZ-241 provides no OAT interface. The customer may either add an additional OAT probe (ID 11) or use the
internal constant (ID 12). ID 11 is to be recommended in operations in temperature extremes.