Honeywell MKXXII Crib Toy User Manual


 
Honeywell
MK XXII EGPWS Installation Manual
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C
SHEET
188
TABLE E 3.1.1-12
TORQUE DATA SELECT 14 (COAST GUARD HH-65)
SIGNAL CONNECTION SUMMARY DATA
Engine Torque #1 (+) = J1-26
(-) = J1-27
Format: DC
Input Type: Basic
Fault Designation: ENGINE TORQUE 1
Validity: none
Engine Torque #2 (+) = J1-66
(-) = J1-47
Format: DC
Input Type: Basic
Fault Designation: ENGINE TORQUE 2
Validity: none
TABLE E3.1.1-13
: TORQUE DATA SELECT 15 (GENERIC FIXED TORQUE 20%)
SIGNAL CONNECTION SUMMARY DATA
Engine Torque #1 No Connection Format: Fixed Internal
Input Type: Basic
Fault Designation:
Engine Torque #2 No Connection Format: Fixed Internal
Input Type: Basic
Fault Designation:
TABLE E3.1.1-14
TORQUE DATA SELECT 16 (COMMON DC TORQUE)
SIGNAL CONNECTION SUMMARY DATA
Engine Torque #1 (+) = J1-26
(-) = J1-27
Format: DC
Input Type: Basic
Fault Designation: ENGINE TORQUE 1
Engine Torque #2 (+) = J1-66
(-) = J1-47
Format: DC
Input Type: Basic
Fault Designation: ENGINE TORQUE 2
TABLE E3.1.1-15
TORQUE DATA SELECT 17 (GENERIC SHADIN DC TO 429 CONVERTER)
CHANNEL
RX429-8
CONNECT TO:
Eng #1 (high speed)
Fault Designation: ENGINE 1 BUS
Bus Type: Basic
A = J2-24
B = J2-07
Data
Torque 1
Torque 2
Label
053
054
Sig. Bits
15
15
Range
0 to 180%
0 to 180%
Signal Type
Basic
Basic
Resolution
0. 0078125
0. 0078125
Rate (ms)
50
50
Note 1: The actual number of significant bits is 16 but 15 bits will support the data range. This is adjusted to make the input
processing work with the actual MSB = to bit 29.