Table E 3.1.6-6 Collins ProLine II (5x4,5x5)
DISPLAY CONFIGURATION GROUP 3 (COLLINS PROLINE II, 5X4, 5X5)
Function Value
Display Type Collins ProLine II (5x4, 5x5) Display
Sweep Type Standard with +/-60 degree limit
Category 7, Options Select Group #1
TA&D Alternate Pop Up: False TA&D Alternate Pop Up: True
Auto Pop Up
Pop Up On Caution or Warning Never Pop Up
Category 7, Options Select Group #1
Peaks Enabled: False Peaks Enabled: True
Peaks Mode
(Available as of –003)
Peaks Off Peaks On
Auto Range No
Moving Marker No
Overlay Page Yes; “TERR” is located on the right side of display.
“TERR” or Peaks Elevations located on upper left side of Terrain image
as of -003.
Display bus type Standard ARINC 453
DISPLAY BUS #1
453TX_1
CONNECT TO:
A = J1-58
B = J1-59
Terrain Display data to switching relay/Symbol Generator
DISPLAY BUS #2
453TX_2
CONNECT TO:
A = J1-56
B = J1-57
Terrain Display data to switching relay/Symbol Generator
DISPLAY INPUT CONTROL GROUP 1
CHANNEL
429_422RX_1
CONNECT TO:
WX-IND 429 out (range)
Bus 1 (Low Speed)
Fault Designation: DISPLAY BUS 1
Bus Type: Basic
A = J2-37
B = J2-36
Data
Range (Display Word 2)
Label
271
Sig. Bits
Discrete
Range
5-320NM
Signal Type
Basic
Resolution
N/A
Rate (ms)
100
CHANNEL
429RX_3
CONNECT TO:
WX-IND 429 out (range)
Bus 2 (Low Speed)
Fault Designation: DISPLAY BUS 2
Bus Type: Basic
A = J2-41
B = J2-40
Data
Range (Display Word 2)
Label
271
Sig. Bits
Discrete
Range
5-320NM
Signal Type
Basic
Resolution
N/A
Rate (ms)
100
CONN PIN # REFERENCE NAME PIN FUNCTION Polarity/Configuration
J1-32 GND_DISC_12 Display Select Discrete #1 Type 1 (Momentary)
Gnd = Display Select Toggle
<not> Gnd = Normal
J1-31 GND_DISC_13 Display Select Discrete #2 Type 1 (Momentary)
Gnd = Display Select Toggle
<not> Gnd = Normal
OUTPUT 429 BUS GROUP 0
Channel Pins Comments
429TX_1 (Low Speed) A = J2-43 B = J2-42 Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x and 7.1.4.x
429TX_2 A = J2-26 B = J2-9 No Connection (No Data Output)
Integration note:
When interfacing to a single display controller configuration the bus must be connected to both EGPWS input channels. This
prevents the EGPWS from reporting an external bus fault on the second channel.