Honeywell
MK XXII EGPWS Installation Manual
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C
SHEET
186
TABLE E 3.1.1-4
TORQUE DATA SELECT 4 (EC-155B, AS-365N3)
CHANNEL
RX429-8
CONNECT TO:
Eng #1 (high speed)
Fault Designation: ENGINE 1 BUS
Bus Type: Basic
A = J2-24
B = J2-07
Data
Torque
Label
053
Sig. Bits
15
Range
0 to 180%
Signal Type
Basic
Resolution
0. 0078125
Rate (ms)
20
CHANNEL
RX429-5
(Note 1)
CONNECT TO:
Eng #2 (high speed)
Fault Designation: ENGINE 2 BUS
Bus Type: Basic
A = J2-21
B = J2-04
Data
Torque
Label
053
Sig. Bits
15
Range
0 to 180%
Signal Type
Basic
Resolution
0. 0078125
Rate (ms)
20
Note 1: Digital Radar Altitude (type 2) can not be used with this configuration.
TABLE E 3.1.1-5
TORQUE DATA SELECT 5 (MD900/902, AGUSTA 109E)
CHANNEL
429_422RX_1
Note 1
CONNECT TO:
Eng #1
Fault Designation: ENGINE 1 BUS
Bus Type: (RS-422 – 9600 baud)
A = J2-36
B = J2-37
Data
Torque
Torque Valid
Word
5
13
Sig. Bits
15
16
Range
256%
N/A
Signal Type
Basic
Basic
Resolution
0.0078125
N/A
Rate (ms)
250
250
CHANNEL
RX422-2
Note 1
CONNECT TO:
Eng #2
Fault Designation: ENGINE 2 BUS
Bus Type: (RS-422 – 9600 baud)
A = J2-10
B = J2-11
Data
Torque
Torque Valid
Word
5
13
Sig. Bits
15
16
Range
256%
N/A
Signal Type
Basic
Basic
Resolution
0.0078125
N/A
Rate (ms)
250
250
Note 1: This type is only compatible with display type 242 that uses RX429-8 for range control.
TABLE E 3.1.1-6
TORQUE DATA SELECT 6 (SUPER PUMA)
SIGNAL CONNECTION SUMMARY DATA
Engine Torque #1 (+) = J1-26
(-) = J1-27
Format: DC
Input Type: Basic
Fault Designation: ENGINE TORQUE 1
Validity: none
Engine Torque #2 (+) = J1-66
(-) = J1-47
Format: DC
Input Type: Basic
Fault Designation: ENGINE TORQUE 2
Validity: none
TABLE E 3.1.1-7
TORQUE DATA SELECT 7 (AS365 DAUPHIN N1 & N2)
SIGNAL CONNECTION SUMMARY DATA
Engine Torque #1 (+) = J1-26
(-) = J1-27
Format: DC
Input Type: Basic
Fault Designation: ENGINE TORQUE 1
Validity: none
Engine Torque #2 (+) = J1-66
(-) = J1-47
Format: DC
Input Type: Basic
Fault Designation: ENGINE TORQUE 2
Validity: none