MK XXII EGPWS Installation Manual
CAGE CODE: 97896 SCALE: NONE SIZE: A DWG NO: 060-4314-225 REV: C
SHEET
62
3.3.2.2 Examples
3.3.2.3 Analog altitude and 500 ohm OAT
62
43
9
25
63
44
53
J1
Altitude Out
Signal Common
BIT Out
Analog Air Data ComputerEGPWS MK XXII
(+)
(-)
Uncorrected
Barometric
Altitude
Baro Altitude Valid +28V
(+)
(-)
Temp. Input
Chassis Ground
+5V Excitation
500 ohm
Temperature
Probe
Analog-ADC.vsd
Cat 2 Uncorrected Baro Altitude
Vendor Model ID Altitude Out Common BIT Out
CIC 04077 0 J1-F J1-G J1-E
Collins ADS-65 3 J1-12 J1-13 J1-5
CIC 02702 4 J1-A J1-B J1-E
Honeywell AZ-241 11/12 J1-63 J1-11 J1-12
Honeywell AZ-242 11/12 J1A-40 J1A-11 J1A-12
Honeywell AZ-648 11/12 J1-J J1-G J1-U
Honeywell AZ-800 11/12 J1A-78 J1A-10 J1A-34
Honeywell AZ-810 11/12 J1A-78 J1A-10 J1A-34
NOTE: The connector pin numbers given in the Table above are to the best knowledge of Honeywell EGPWS
engineering. Please contact the manufacturer’s customer service to confirm your installation.
NOTE: Honeywell AZ-810 should only be used as an analog source if it does not have a digital interface.
NOTE: The CIC 02702 scaling was changed in –008 software. The analog barometric altitude conversion to barometric
altitude rate noise problem was fixed in –008 software.