Table Table E 3.1.6-1 No Display – TAD and TCF Enabled
OUTPUT 429 BUS GROUP 0
Channel Pins Comments
429TX_1 (Low Speed) A = J2-43 B = J2-42 Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x and 7.1.4.x
429TX_2 A = J2-26 B = J2-9 No Connection (No Data Output)
Table Table E 3.1.6-2 TA&D / TCF Disabled
OUTPUT 429 BUS GROUP 0
Channel Pins Comments
429TX_1 (Low Speed) A = J2-43 B = J2-42 Transmits (Section 7) Label sets: 7.1.1.x, 7.1.2.x, 7.1.3.x and 7.1.4.x
429TX_2 A = J2-26 B = J2-9 No Connection (No Data Output)