APPENDICES
Appendix 1 Differences with the Q Series Project
This chapter explains about the GX Developer functions, except for the functions
described in Chapter 5 "ADDED FUNCTIONS TO CORRESPOND TO A SAFETY
PROGRAMMABLE CONTROLLER", added to/updated from the Basic model QCPU
project
(1) Differences with the parameters
(a) [PLC RAS] setting on PLC parameter.
Consistency check for setting time on WDT setting and constant scanning.
Setting time for constant scanning should not exceed WDT setting's setting
time.
Constant scanning
WDT setting
(b) [CC-Link] setting on Network parameter.
Default value for "Scan mode setting" is "Synchronous".
(2) Differences in the Project menu
(a) Programmable controller type change
The project for a safety programmable controller cannot be changed its
programmable controller type.
Furthermore, the programmable controller type of the project created by
other than a safety programmable controller cannot be changed to the
QSCPU.
(b) Ladder copy/paste
The ladder created in a safety programmable controller project can only be
copied to/pasted in (a) safety programmable controller project(s).
(c) Print
The following functions have been added or updated.
1) The print function of "Safety settings" of PLC parameter, "Safety remote
station settings" of network parameter (CC-Link), "Network
Configuration Setting", "Network Operation Setting", "safety
communication settings" of network parameter (Ethernet/CC
IE/MELSECNET) are added.
Print example of "Safety setting"
APP