Table A-2 Power Output Parameter Block Values Level 1 Continued
Level 1 Blocks - Continued
Block Title Parameter P# Adjustable Range Factory User
Setting
INPUT OPERATING MODE 1401 1– KEYPAD
2– STANDARD RUN
3– 15SPD
4– 3SPD ANA 2WIRE
5– 3SPD ANA 3WIRE
6– SERIAL
7– BIPOLAR
8– PROCESS MODE
9– EPOT –2WIRE
10– EPOT –3WIRE
KEYPAD
COMMAND SELECT 1402 0– POTENTIOMETER
1– +/-10 VOLTS
2– +/-5 VOLTS
3– 4 To 20 mA
4– 10V W/TORQ FF
5– EXB PULSE FOL
6– 5VOLT EXB
7– 10 VOLT EXB
8– 4-20mA EXB
9– 3-15 PSI EXB
10– TACHOMETER EXB
11– SERIAL
12– NONE
+/-10
VOLTS
ANA CMD INVERSE 1403 0–OFF, 1– ON OFF
ANA CMD OFFSET 1404 -20.0 TO +20.0%
(where ±0.5V=±20%)
0.0 %
ANA 2 DEADBAND 1405 0-10.00 V 0.00 V
ANA 1 CUR LIMIT 1406 0–OFF, 1– ON OFF
OUTPUT OPTO OUTPUT #1 1501 0– READY
1– ZERO SPEED
2– AT SPEED
READY
OPTO OUTPUT #2 1502
3– OVERLOAD
4– KEYPAD CONTROL
5– AT SET SPEED
6– FAULT
7– FOLLOWING ERR
ZERO
SPEED
OPTO OUTPUT #3 1503
8– MOTR DIRECTION
9– DRIVE ON
10– CMD DIRECTION
11– AT POSITION
AT SPEED
OPTO OUTPUT #4 1504
12– OVER TEMP WARN
13– PROCESS ERROR
14– DRIVE RUN
15– SERIAL
FAULT
ZERO SPD SET PT 1505 1-MAX Speed 200 RPM
AT SPEED BAND 1506 1-1000 RPM 100 RPM
SET SPEED 1507 0-MAX Speed Rated Motor
Speed