6. Axis Specifications Parameters
6.3 Absolute Position Parameters
76
# Items Details
Setting range (unit)
2054 clpush Current limit
(%)
Set up the current limit value for the initial setting when
detecting an absolute position with a dog-less system.
The setup value is the ratio of the current limit value to
the rated value.
0 to 100 (%)
2055 pushf Push speed Set the feedrate for the automatic initial setting during
stopper method.
1 to 999 (mm/min)
2056 aproch Approach Set the approach distance for the automatic initial
setting in the stopper method.
Approach distance: After pushing onto the machine
stopper once‚ the tool returns this
distance‚ and then pushes again.
When set to 0‚ the reference point coordinates set in
"#2037 G53ofs" will be used as the approach start
position.
0 to 999.999 (mm)
2057 nrefp Near zero
point +
Set the width where the near-reference-point signal is
output. (Positive direction width)
When set to 0‚ the width is equivalent to the grid width
setting.
0 to 32.767 (mm)
2058 nrefn Near zero
point −
Set the width where the near-reference-point signal is
output. (Negative direction width)
When set to 0‚ the width is equivalent to the grid width
setting.
0 to 32.767 (mm)
2059 zerbas Select zero
point
parameter
and
reference
point
Specify the position to be the zero point coordinate
during absolute position initial setting.
0: Machine stopper position in machine stopper
method.
Marked point in marked point alignment method.
1: On the grid point just before machine stopper in
machine stopper.
On the grid point just before the marked point in
marked point alignment method.
0/1