Mitsubishi Electronics C64T Crib Toy User Manual


 
8. Spindle Parameters
8.4 MDS-C1-SPM
261
No. Items Details
Setting
range
Standard
setting
3407 SP207 GDL Sequential
mode startup
timing
To carry out spindle synchronization or C-axis
control in the both-chuck state with no
movement immediately after the power is
turned ON, set this parameter so that the
reverse run detection function will function
correctly. Set so that servo ON timing for the
opposing spindle has the combination of (1)
and (2) shown in the drawing below.
0: Servo turns ON simultaneously with servo
ON command, and servo ON status is
returned immediately.
1: Gate turns ON at pattern (1) shown below,
and servo ON status is returned two
seconds later.
2: Gate turns ON at pattern (2) shown below,
and servo ON status is returned two
seconds later.
0/1/2 0
Servo ON command
Servo ON (1)
Servo ON (2)
Servo ON status
700ms
300ms
700ms
300ms
2s
Gate ON
Servo ON
Gate ON
3408 SP208 W2 This is used by Mitsubishi.
Set to "0" unless particularly designated.
0 0
3409
to
3413
SP209
to
SP213
Not used. Set to "0". 0 0
3414 SP214 TZRN Synchronized
tapping
zero point
return speed
This parameter is valid when SP193 (SPECT)
bitE is set to "0".
Set the zero point return speed used when
the speed loop changes to the position loop.
3415 SP215 TPDT Synchronized
tapping
zero point
return
deceleration
rate
This parameter is valid when SP193 (SPECT)
bitE is set to "0".
Set the deceleration rate where the machine
starts to decelerate when it returns to the
target stop point during synchronized tapping
zero point return.
When the machine tends to overshoot at the
stop point set a smaller value.
0 to 10000
(pulse)
1
3416 SP216 TPST Synchronized
tapping
zero point
return shift
amount
This parameter is valid when SP193 (SPECT)
bitE is set to "0".
Set the synchronized tapping zero point
position.
0 to 4095 0