Mitsubishi Electronics C64T Crib Toy User Manual


 
5. Base Specifications Parameters
42
# Items Details
Setting range (unit)
1210 RstGmd Modal G
code reset
L system
Specify a
hexadecimal
number.
1211 FHtyp Feed hold
stop type
Specify the type of the external signal used for feed
hold.
0: Disable the external signal.
1: Enable the external signal (contact A)
2: Enable the external signal (contact B)
0 to 2
1212 FHno Feed hold
external
signal
device
Specify the number (X??) of the device used to input
the feed hold signal.
(Note) The setting range of this parameter has been
expanded on the software Ver.D0 and later.
000 to 3FF
(hexadecimal)
1216 extdcc External
deceleration
level
Use an upper limit value at the feedrate indicated when
validating external deceleration signals.
1 to 1000000
(mm/min)
1217 aux01 Not used.
0 Group 1 Move G modal
1 Group 2 Flat selection modal
2 Group 3 Absolute/increment command modal
3 Group 4 Barrier check modal
4 Group 5 Feed G modal
5 Group 6 Inch/metric modal
6 Group 7 Nose radius compensation modal
7
8
9 Group 10 Fixed cycle return command modal
A
B Group 12 Workpiece coordinate system modal
C Group 13 Cut modal
D
E
F
10 Group 17 Constant surface speed control command modal
11 Group 18 Balance cut
12
13 Group 20 Spindle 2 control modal
14 Group 15 Double-turret mirror image
15
16
17
18
19
1A
1B
1C
1D
1E
1F