Mitsubishi Electronics C64T Crib Toy User Manual


 
8. Spindle Parameters
8.4 MDS-C1-SPM
242
No. Items Details
Setting
range
Standard
setting
3241
(PR)
SP041 PTYP Power supply
type
Power supply type
0000 to
FFFF
HEX
setting
0000
3242
(PR)
SP042 CRNG C-axis detector
range
This parameter is used to set the C-axis
detector range.
Set "0" for this parameter.
"2" is used by Mitsubishi for testing.
0 to 7 0
F E D C B A 9 8
amp rtyp
7 6 5 4 3 2 1 0
ptyp
bit Explanation
0
1
2
When the CN4 connector of the drive unit and the power supply are
connected, setting below is necessary.
To validate the external emergency stop function, add 40h.
3
Set-
ting
0x 1x 2x 3x 4x 5x 6x 7x 8x
4
x0
Not
used
CV-300
5
x1
CV-110 CR-10
6
x2
CV-220 CR-15
7
ptyp
x3
CR-22
x4
CV-37 CR-37
x5
CV-150 CV-450 CV-550
x6
CV-55 CV-260 CR-55
x7
CV-370
x8
CV-75 CR-75
x9
CV-185 CR-90
8 Set the regenerative resistor type when MDS-A-CR is used.
9
Set-
ting
Regenerative resistor
model name
Resistance
value
Capacity
A 0 MDS-C1-CV (Setting when using power supply regeneration)
B
rtyp
1 GZG200W260HMJ
26
80W
2
GZG300W130HMJ×2 26
150W
3 MR-RB30
13
300W
4 MR-RB50
13
500W
5
GZG200W200HMJ×3 6.7
350W
6
GZG300W200HMJ×3 6.7
500W
7 R-UNIT-1
30
700W
8 R-UNIT-2
15
700W
9 R-UNIT-3
15
2100W
A to D No setting
E Large capacity + ready ON high-speed sequence
F Ready ON high-speed sequence
C
D
E
F
amp
Always set to “0”.