7. Servo Parameters
7.2 MDS-C1-Vx High-gain (MDS-B-Vx4 Compatible)
113
No. Items Details Setting range
2221 SV021
OLT
Overload
detection
time
constant
Set the detection time constant of Overload 1 (Alarm 50).
Set to “60” as a standard. (For machine tool builder
adjustment.)
1 to 999
(s)
2222 SV022
OLL
Overload
detection
level
Set the current detection level of Overload 1 (Alarm 50) in
respect to the stall (rated) current. Set to “150” as a
standard. (For machine tool builder adjustment.)
110 to 500
(Stall [rated]
current %)
Set the excessive error detection width when servo ON.
<Standard setting value>
Rapid traverse rate
(mm/min)
OD1=OD2=
60*PGN1
/2 (mm)
2223 SV023
OD1
Excessive
error
detection
width during
servo ON
When “0” is set, the excessive error detection will not be
performed.
0 to 32767
(mm)
2224 SV024
INP
In-position
detection
width
Set the in-position detection width.
Set the accuracy required for the machine.
The lower the setting is, the higher the positioning
accuracy gets, however, the cycle time (setting time)
becomes longer. The standard setting is “50”.
0 to 32767