Mitsubishi Electronics C64T Crib Toy User Manual


 
8. Spindle Parameters
8.4 MDS-C1-SPM
265
No. Items Details
Setting
range
Standard
setting
3453 SP253
DA1NO D/A output
channel 1
data number
Set the output data number for channel 1
of the D/A output function.
When set to "0", the output is
speedometer.
Refer to "9.4 (1) For D/A output functions".
–32768 to
32767
0
3454 SP254 DA2NO D/A output
channel 2
data number
Set the output data number for channel 2
of the D/A output function.
When set to "0", the output is load meter.
Refer to "9.4 (1) For D/A output functions".
–32768 to
32767
0
3455 SP255 DA1MPY DA output
channel 1
magnifica-
tion
Set the data magnification for channel 1 of
the D/A output function.
The output magnification is the setting
value divided by 256.
When set to "0", the output magnification
becomes 1-fold, in the same manner as
when "256" is set.
Refer to "9.4 (1) For D/A output functions".
–32768 to
32767
(1/256-fold)
0
3456 SP256 DA2MPY DA output
channel 2
magnifica-
tion
Set the data magnification for channel 2 of
the D/A output function.
The output magnification is the setting
value divided by 256.
When set to "0", the output magnification
becomes 1-fold, in the same manner as
when "256" is set.
Refer to "9.4 (1) For D/A output functions".
–32768 to
32767
(1/256-fold)
0
3457
(PR)
to
3520
(PR)
SP257
to
SP320
RPM
BSD
Motor
constant
(H coil)
This parameter is valid only in the
following two conditional cases:
(a) In case that SP034 (SFNC2) bit0=1
and SP034 (SFNC2) bit2=0
Set the motor constants when using a
special motor, not described in the
SP040 (MTYP) explanation and when
not using the coil changeover motor.
(b) In case that SP034 (SFNC2) bit0=1
and SP034 (SFNC2) bit2=1
Set the motor constant of the H coil of
the coil changeover motor.
(Note) It is not allowed for the user to
change the setting.
0000 to
FFFF
HEX setting
0000
3521
(PR)
to
3584
(PR)
SP321
to
SP384
RPML
BSDL
Motor
constant
(L coil)
This parameter is valid only in the
following conditional case:
(a) In case that SP034 (SFNC2) bit0=1
and SP034 (SFNC2) bit2=1
Set the motor constant of the L coil of
the coil changeover motor.
(Note) It is not allowed for the user to
change the setting.
0000 to
FFFF
HEX setting
0000