Chapter 5 Work in Edit mode 73
Map a screen control to multiple parameters
You can map a single screen control to multiple parameters and control how the screen control
modies each mapped parameter. Mapping a screen control to multiple parameters is also
referred to as multimapping. You map a screen control to up to eight parameters by adding
mappings in the Screen Control Inspector.
If you create multiple mappings for a screen control, you can dene the relationships between
the rst mapping and subsequent mappings. This can be especially useful when, for example,
you are mapping the same control to lter cuto and lter resonance, and you want to ensure
that resonance does not exceed a certain maximum value as you increase the cuto value. The
default relationship aects all future mappings (for the same and other screen controls), but does
not aect existing mappings. The default is set to Scale the rst time you open MainStage.
Add a mapping
1 Map the screen control to a parameter or action, as described in Map screen controls to channel
strip and plug-in parameters on page 69 and Map screen controls to actions on page 71.
2 With the screen control selected, click the Add Mapping (+) button at the upper-right corner of
the Screen Control Inspector.
A new Unmapped tab appears in the Inspector, showing the Parameter Mapping browser.
3 In the Parameter Mapping browser, choose the parameter to which you want to map the
screen control.
If you add a mapping while the Learn process is active (the Assign & Map button is red), you can
immediately learn the new mapping. There are key commands for selecting the previous and
next tab to make mapping to multiple parameters easier. For more information, see Parameter
mapping (Edit mode) on page 153.
View all mappings for a screen control
m In the Screen Control Inspector, click the Mappings tab.
The mappings appear in a list view that shows the minimum and maximum range values and
patch change behavior for each mapping and includes buttons to open the Parameter graph
and Invert graph values for each mapping.
Dene the default relationship between the rst mapping and subsequent mappings
1 Select a screen control you want to map to multiple parameters.
2 Choose Default Relation to First Mapping from the Action pop-up menu, located in the upper-
right corner of the Screen Control Inspector.
3 Do one of the following:
•
To set subsequent mappings to be oset by a xed value from the rst mapping: Choose Oset.
•
To set subsequent mappings to scale by a constant ratio, starting from the same minimum value:
Choose Scale.
•
To set subsequent mappings to scale by a constant ratio to the point dened for the mapping,
starting from both the same minimum value and maximum value: Choose Pivot.