2.
Set the Options DIP switches by following these
guidelines:
Switch 1 sets all system transmitters in the interior zone to
either of the following
ON =
interior delayed
OFF = interior instant
Switch 2 determines whether the Central Controller’s
internal
sounder is on or off during an intrusion alarm.
ON = silent
OFF =
on
Switch 3 sets the Central Controller's
hardwired sensor
loop to either of the following:
ON =
open loop
OFF =
closed loop
Switch 4 sets the Central Controller’s hardwired loop zone
to either of the following:
ON
=
interior
OFF = perimeter instant
B. Mount the Central Controller
Use
#8
screws. PLEASE USE A SMALL LEVEL TO MAKE
SURE THE HOUSING IS LEVEL BEFORE YOU TIGHTEN
THE SCREWS.
Good!Before you begin wiring in all the components, please take a look at the diagram of the Central
Controller Terminal Strip on the next page. Each terminal screw is labeled for your information.
AT&T Proprietary Information
2-21