Section 11 Multi-Function Timer Pulse Unit 2
Page 580 of 2108 R01UH0134EJ0400 Rev. 4.00
Sep 24, 2014
SH7262 Group, SH7264 Group
Note: This function must be used in combination with interrupt skipping.
When interrupt skipping is disabled (the T3AEN and T4VEN bits in the timer interrupt
skipping set register (TITCR) are cleared to 0 or the skipping count set bits (3ACOR and
4VCOR) in TITCR are cleared to 0), make sure that A/D converter start requests are not
linked with interrupt skipping (clear the ITA3AE, ITA4VE, ITB3AE, and ITB4VE bits in
the timer A/D converter start request control register (TADCR) to 0).
TADCORA_4
TCNT_4
A/D converter start request (TRG4AN)
Note: * When the interrupt skipping count is set to two.
TGIA_3 interrupt
skipping counter
TCIV_4 interrupt
skipping counter
TGIA_3 A/D request-enabled
period
TCIV_4 A/D request-enabled
period
When linked with TGIA_3 and TCIV_4
interrupt skipping
When linked with TGIA_3
interrupt skipping
When linked with TCIV_4
interrupt skipping
00 01 00 0102
00 01 00 0102
(UT4AE/DT4AE = 1)
Figure 11.75 Example of A/D Converter Start Request Signal (TRG4AN) Operation Linked
with Interrupt Skipping