Renesas R5S72647 Doll User Manual


  Open as PDF
of 2152
 
Section 15 Serial Communication Interface with FIFO
Page 730 of 2108 R01UH0134EJ0400 Rev. 4.00
Sep 24, 2014
SH7262 Group, SH7264 Group
Bit Bit Name
Initial
Value R/W Description
1 RDF 0 R/(W)* Receive FIFO Data Full
Indicates that receive data has been transferred to the
receive FIFO data register (SCFRDR), and the
quantity of data in SCFRDR has become more than
the receive trigger number specified by the RTRG[1:0]
bits in the FIFO control register (SCFCR).
0: The quantity of transmit data written to SCFRDR is
less than the specified receive trigger number
[Clearing conditions]
RDF is cleared to 0 by a power-on reset, standby
mode
RDF is cleared to 0 when the SCFRDR is read
until the quantity of receive data in SCFRDR
becomes less than the specified receive trigger
number after 1 is read from RDF and then 0 is
written
RDF is cleared to 0 when the direct memory
access controller is activated by receive FIFO data
full interrupt (RXI) and read SCFRDR until the
quantity of receive data in SCFRDR becomes less
than the specified receive trigger number
1: The quantity of receive data in SCFRDR is more
than the specified receive trigger number
[Setting condition]
RDF is set to 1 when a quantity of receive data
more than the specified receive trigger number is
stored in SCFRDR*
1
Note: 1. As SCFTDR is a 16-byte FIFO register,
the maximum quantity of data that can be
read when RDF is 1 becomes the
specified receive trigger number. If an
attempt is made to read after all the data
in SCFRDR has been read, the data is
undefined. The quantity of receive data in
SCFRDR is indicated by the lower 8 bits
of SCFDR.