Renesas R5S72623 Doll User Manual


  Open as PDF
of 2152
 
Section 15 Serial Communication Interface with FIFO
Page 754 of 2108 R01UH0134EJ0400 Rev. 4.00
Sep 24, 2014
SH7262 Group, SH7264 Group
Transmitting Serial Data (Asynchronous Mode)
Figure 15.4 shows a sample flowchart for serial transmission.
Use the following procedure for serial data transmission after enabling transmission.
Start of transmission
Read TDFE flag in SCFSR
TDFE = 1?
Write transmit data in SCFTDR,
and read 1 from TDFE flag
and TEND flag in SCFSR,
then clear to 0
All data transmitted?
Read TEND flag in SCFSR
TEND = 1?
Break output?
Clear SPB2DT to 0 and
set SPB2IO to 1
Clear TE bit in SCSCR to 0
End of transmission
No
Yes
No
Yes
No
Yes
No
Yes
[1] Status check and transmit data write:
Read SCFSR and check that the
TDFE flag is set to 1, then write
transmit data to SCFTDR, and read 1
from the TDFE and TEND flags, then
clear to 0.
The quantity of transmit data that can
be written is 16 - (transmit trigger set
number).
[2] Serial transmission continuation
procedure:
To continue serial transmission, read
1 from the TDFE flag to confirm that
writing is possible, then write data to
SCFTDR, and then clear the TDFE
flag to 0.
[3] Break output during serial
transmission:
To output a break in serial
transmission, clear the SPB2DT bit to
0 and set the SPB2IO bit to 1 in
SCSPTR, then clear the TE bit in
SCSCR to 0.
In [1] and [2], it is possible to ascertain
the number of data bytes that can be
written from the number of transmit data
bytes in SCFTDR indicated by the upper
8 bits of SCFDR.
[1]
[2]
[3]
Figure 15.4 Sample Flowchart for Transmitting Serial Data