Section 15 Serial Communication Interface with FIFO
R01UH0134EJ0400 Rev. 4.00 Page 745 of 2108
Sep 24, 2014
SH7262 Group, SH7264 Group
15.3.12 Line Status Register (SCLSR)
The CPU can always read or write to SCLSR, but cannot write 1 to the ORER flag. This flag can
be cleared to 0 only if it has first been read (after being set to 1).
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0000000000000000
R R R R R R R R R R R R R R R R/(W)*
Bit:
Initial value:
R/W:
Note: Only 0 can be written to clear the flag after 1 is read.*
- - - - - - - - - - - - - - - ORER
Bit Bit Name
Initial
Value
R/W Description
15 to 1 All 0 R Reserved
These bits are always read as 0. The write value
should always be 0.
0 ORER 0 R/(W)* Overrun Error
Indicates the occurrence of an overrun error.
0: Receiving is in progress or has ended normally*
1
[Clearing conditions]
ORER is cleared to 0 when the chip is a power-on
reset
ORER is cleared to 0 when 0 is written after 1 is
read from ORER.
1: An overrun error has occurred*
2
[Setting condition]
ORER is set to 1 when the next serial receiving is
finished while the receive FIFO is full of 16-byte
receive data.
Notes: 1. Clearing the RE bit to 0 in SCSCR does
not affect the ORER bit, which retains its
previous value.
2. The receive FIFO data register
(SCFRDR) retains the data before an
overrun error has occurred, and the next
received data is discarded. When the
ORER bit is set to 1, the next serial
reception cannot be continued.