C-2 PathBuilder S24x, 26x, and 27x Switch Error Codes
Note
During a warm start, display sequencing starts with the “L2” code.
48 OFF ON FLASH write failure
49 OFF ON Read error on Port 6
60 OFF ON Local DRAM exhausted
8.8. ON OFF PBIST (~3 seconds)
(Blank) OFF OFF PBIST lamp-off test (~.5 seconds)
L0 OFF OFF Load Phase 0—PROM IPL loads the FLASH
IPL image, (~ 1 second)
L1 OFF OFF Load Phase 1—FLASH IPL decompresses and
loads the FBIST image (~ 1 second)
(Rotating segments) ON OFF FBIST lamp test (~ 2 seconds)
L2 OFF OFF Load Phase 2—FLASH IPL decompresses and
loads the ONS image (several seconds)
L3 OFF OFF Load Phase 3—STARTUP inventories the
modules in ONS image (~ 3 seconds)
L4 OFF OFF Load Phase 4—SYSINIT inits memory mgmt.
and all ONS modules (~10 seconds)
CR OFF ON PathBuilder S24x, 26x, and 27x switch has
crashed
(Blank with flashing
dashes)
OFF OFF Normal system operation
Numeric
Display (continued)
Status
LED
Service
LED
Description/Comments