8. Input menu
Image 8-7
Image 8-8
Image 8-9
When:
Free run Output is locked on an internal sync (60 Hz)
Automatic Output is locked on the selected input for the main window
Input 1 Output is locked on source 1
Input 2 Output is locked on source 2
Input 3 Output is locked on source 3
Input 4 Output is locked on source 4
The options menu changes depending on the selection.
When Input locking is set to Automatic or on a specific input and there is no sync signal available, the locking
will be switched to Free run without changing the user settings. Once the sync is available, it applies again
the user settings.
Options for Free run
When Free run is selected (arrow in front of it) and then the Options are selected, the following menu appears:
Image 8-10
Use the ▲ or ▼ key to select Manual lock and press ENTER to toggle between On and Off.
Manual lock on : locking is done on the indicated vertical frequency which can be changed by the user.
Manual lock off : locking is done on an internal sync (60 Hz).
To change the locking frequency for manual lock on, use the ▲ or ▼ key to select Vert freq and press ENTER to activate. The first
digit is selected.
Use the ▲ or ▼ key to select the desired digit and press ◄ or ► key to select the next digit in the address or enter the value with
the digit keys on the remote control or local keypad. The next digit in the value will be automatically selected.
Options for Automatic or specific input
When Automatic or specific input is selected (arrow in front of it) and then the Options are selected, the following menu appears:
Image 8-11
Use the ▲ or ▼ key to select Genlock and press ENTER to toggle between On and Off.