Barco RS976986/08 Crib Toy User Manual


 
5. Connections
female XLR output port (N). So, the following projector in the daisy chain will still receive his RC5 code. Note that the RC5 in/out
signals are without carrier.
Mini jack plug
XLR – Remote CTRL in XLR – Remote CTRL out
Pin Description Pin Description Pin Description
SGND
1
GND
1
GND
T
RC5 in
2
RC5 in
2
RC5 out
R
n.c. or GND
3 XLR present sense 3 XLR present sense
S R T
A B C
1
2
3
2 1
3
PUSH
Image 5-12
A Mini stereo jack plug.
S : SLeeve (shield)
•R:Ring
•T:Tip
B Male XLR socket.
C Female XLR socket.
RS232/422 serial communication
The communication interface of the FLM HD18 supports RS232 and RS422 serial communication. You can use the RS232/RS422
input port (O) to connect a local PC to your FLM projector. This way you can congure and control your FLM projector from your
local PC.
Do not forget to set the projector’s baud rate (default = 115200) to match that of the computer.
The communication interface has also an active RS232/RS422 loop through output port (E). Whenever the projector has no power, a
passive loop through is created from the RS232/RS422 input port (O) to theRS232/RS422 output port (E). So, the following projector
in the daisy chain will still receive his RS232/RS422 commands.
Advantages of using RS232/RS422 serial communication:
easy adjustment of the projector via PC (or MAC).
allow storage of multiple projector congurations and set ups.
wide range of control possibilities.
address range from 0 to 255.
sending data to the projector (update).
copying data from the projector (backup).
RS232/422 input port RS232/422 output port
Pin Description Pin Description
1 DCD : Data Carrier Detect 1 (not connected) —
2 RXD- : Receive Data 2 RXD- : Receive Data
3 TXD- : Transmitted Data 3 TXD- : Transmitted Data
4 DTR : Data Terminal Ready [RS232]
TXD+ : Transmitted Data [RS422]
4 DTR : Data Terminal Ready [RS232]
TXD+ : Transmitted Data [RS422]
5
GND : Ground
5
GND : Ground
6 DSR : Data Set Ready [RS232]
RXD+ : Received Data [RS422]
6 DSR : Data Set Ready [RS232]
RXD+ : Received Data [RS422]
7
(not connected) —
7
(not connected) —
R5976986 FLM HD18 15/03/2010 39