12 - 14 12 - 14
MELSOFT
12. USEFUL FUNCTIONS
12.4 Auxiliary Functions for Data Input
This section describes the functions which support the setting of parameters and servo
parameters and the input of positioning data and start block data.
12.4.1 Parameter initializing wizard
PURPOS
E
Using the parameter initializing wizard, initialize the parameters and set the axis #1
to #3 parameters.
For the wizard-driven setting, set only the most fundamental items of the basic
parameters 1, OPR basic parameters and OPR extended parameters.
For parameter settings, refer to the AD75 User's Manual.
BASIC OPERATIO
N
1. Display the parameter main screen (refer to Section 8.1).
2. Click the [Tools] → [Initialize parameter] menu.
3. Click the "Yes" button in the parameter initializing wizard start confirmation
dialog box.
When making only the parameter initialization, click "No" button.
4. Set the items to be set for Axis #1 in the Parameter initializing wizard dialog box.
5. After that, make setting in accordance with the screen prompt.
When you selected 2 axes in Change AD75 model, the wizard of Axis #2 starts
after the wizard of Axis #1 is completed.
When you selected 3 axes in Change AD75 model, the wizard of Axis #3 starts
after the wizard of Axis #2 is completed.
When you selected AD75M# in Change AD75 model, the servo parameter
initializing wizard (refer to Section 12.4.2) can be started after the parameter
initializing wizards of all axes are completed.