Mitsubishi Electronics A1SD75P1-S3/P2-S3/P3/S3 Model Vehicle User Manual


 
11 - 39 11 - 39
MELSOFT
11. POSITIONING DEBUGGING
DISPLAY/SETTING DATA
Item Description
JOG speed limit
Shows the JOG operation limit value set to the extended parameters 2 (refer to Section
8.1.4).
JOG speed
Set the speed for JOG operation.
You cannot set any value beyond the JOG speed limit.
Fwd JOG (
)
Rev JOG (
)
Choose the arrow (
, ) of the axis for JOG operation, move the mouse pointer to the
arrow, and press the mouse's left button or the space key to start JOG operation.
Hold down the mouse's left button or the space key to continue JOG operation.
The arrow is red during operation.
"#1 stop" button
"#2 stop" button
"#3 stop" button
Click the corresponding button to stop the axis on which the positioning start test is being
made.
Reset the error after a stop since the axis results in an error occurrence status.
These buttons cannot be clicked during JOG operation.
"All stop" button
Click this button to stop all operating axes.
Reset the error after a stop since the axis results in an error occurrence status.
"Error reset" button
(
/
/ )
Click any button to reset the error of the corresponding axis.
"M code Off" button
(
/
/ )
Click any button to turn off the M code ON signal (XD, XE, XF) of the corresponding axis.