11 - 28 11 - 28
MELSOFT
11. POSITIONING DEBUGGING
11.2.2 Start block data-specified operation
PURPOS
E
Enter the test mode during start block data monitor, and perform test operation
with the specified start block No. and point No.
Check the mode, point, special start condition enable and repeat count set to the
start block data.
BASIC OPERATIO
N
1. Perform the basic operation i Section 11.1.1 to start the start block data monitor.
2. Click the [Online] → [Test] → [Test start] menu (
).
3. Click the "OK" button in the test mode start confirmation dialog box.
4. Click the "Start Condition" button in the Test start/set dialog box.
5. Choose the operating conditions in the Condition data test set dialog box.
6. When you have set the start point, move the cursor to the top line and make
sure that "1" appears in Start No.
7. Click the "OK" button.
8. Select the axis to be started in the Test start/set dialog box and click the "Start"
button.
At this time, test operation is started with the positioning data No. of the axis set
to Start No. "1".
9. To end the start block data test, click the "Exit" button.
10.Clicking the "OK" button in the test mode end confirmation dialog box returns to
the start block data monitor status.
DISPLAY/SETTING SCREEN
1)
12)
13)
6)
7) 9)
10)
8)
11)
18)
17
)
14)
5)
15)
16
)