11 - 7 11 - 7
MELSOFT
11. POSITIONING DEBUGGING
DISPLAY/SETTING SCREE
N
[Start history monitor] [Start with error history monitor]
DISPLAY/SETTING DATA
Item Description
No.
Represents the order of starts since power-on for the start history.
Represents the order of starts after error occurrence for the error-time start history.
If there are more than 16 starts, the older ones are deleted.
For the error-time start history, its data is overwritten every time an error occurs.
Axis
Indicates the axis started.
Buffer memory address: 462 to 622
Start
Indicates the start command destination.
The command destination is the programmable controller CPU, peripheral device or external
start.
Buffer memory address: 462 to 622
Mode
Indicates the type of operation started.
The positioning data No. is displayed for operation which uses the positioning data.
Buffer memory address: 462 to 622
Time
Indicates the error/warning occurrence time in 100ms increments in relation to the time set to
the AD75 in the sequence program.
Buffer memory address: 462 to 622
Result
Shows OK for a normal start.
Shows the error code when an error occurs.
The error code can be confirmed in [Help].
Buffer memory address: 462 to 622