6.3 Extended settings
6.3.1 Web server
Functions The product features an integrated web server.
The web server offers the following features:
•
Display status information
•
Display and change parameters
•
Display and change network settings
•
Display and change Modbus TCP settings
•
Display and change EtherNet/IP settings
•
Display and change settings for the FDR service
•
Display network statistics
•
User-specific adaptation of the website
See chapter "6.3.2 FTP server"
6.3.1.1 Setting the web server
The web server is activated or deactivated by means of the parameter
EthWebserver.
▶
If you do not want to use the web server, set the parameter
EthWebserver to "Off".
Parameter name
HMI menu
HMI name
Description Unit
Minimum value
Factory setting
Maximum value
Data type
R/W
Persistent
Expert
Parameter address
via fieldbus
EthWebserver
Ethernet webserver
0 / Off: Ethernet webserver off
1 / On: Ethernet webserver on
Changed settings become active the next
time the product is switched on.
-
0
1
1
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:6
h
Modbus 17420
Profibus 17420
CIP 168.1.6
6.3.1.2 Accessing the web server
The web server of the product can be accessed via a Web browser.
■
The product must have a valid IP address.
▶
Start an Internet browser.
▶
Enter the IP address of the product in the address bar.
▶
Enter "USER" as the username and the password (uppercase).