5.5 Setting the gateway
The IP address of the gateway is set by means of the parameters
EthIPgate1 ... EthIPgate4.
Set the IP address of the gateway with the parameters
EthIPgate1 ... EthIPgate4.
Parameter name
HMI menu
HMI name
Description Unit
Minimum value
Factory setting
Maximum value
Data type
R/W
Persistent
Expert
Parameter address
via fieldbus
EthIPgate1
ConF CoM-
iPG1
IP address gateway, byte 1
Changed settings become active the next
time the product is switched on.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:F
h
Modbus 17438
Profibus 17438
CIP 168.1.15
EthIPgate2
ConF CoM-
iPG2
IP address gateway, byte 2
Changed settings become active the next
time the product is switched on.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:10
h
Modbus 17440
Profibus 17440
CIP 168.1.16
EthIPgate3
ConF CoM-
iPG3
IP address gateway, byte 3
Changed settings become active the next
time the product is switched on.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:11
h
Modbus 17442
Profibus 17442
CIP 168.1.17
EthIPgate4
ConF CoM-
iPG4
IP address gateway, byte 4
Changed settings become active the next
time the product is switched on.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:12
h
Modbus 17444
Profibus 17444
CIP 168.1.18
5 Commissioning
LXM32M
44
Modbus-TCP module
0198441113843, V1.01, 01.2012