Parameter name
HMI menu
HMI name
Description Unit
Minimum value
Factory setting
Maximum value
Data type
R/W
Persistent
Expert
Parameter address
via fieldbus
EthIPmaster1 IP address master, byte 1
IP address of the master that is permitted to
perform Modbus TCP I/O scanning.
If set to 0.0.0.0 (default), any master can
perform I/O scanning.
Setting can only be changed if power stage
is disabled.
Changed settings become active immedi-
ately.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:29
h
Modbus 17490
Profibus 17490
CIP 168.1.41
EthIPmaster2 IP address master, byte 2
Setting can only be changed if power stage
is disabled.
Changed settings become active immedi-
ately.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:2A
h
Modbus 17492
Profibus 17492
CIP 168.1.42
EthIPmaster3 IP address master, byte 3
Setting can only be changed if power stage
is disabled.
Changed settings become active immedi-
ately.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:2B
h
Modbus 17494
Profibus 17494
CIP 168.1.43
EthIPmaster4 IP address master, byte 4
Setting can only be changed if power stage
is disabled.
Changed settings become active immedi-
ately.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:2C
h
Modbus 17496
Profibus 17496
CIP 168.1.44
5.7.3 Setting the mapping for I/O scanning
The input mapping is set by means of the parameters
EthOptMapInp1 ... EthOptMapInp3.
The output mapping is set by means of the parameters
EthOptMapOut1 ... EthOptMapOut3.
▶
Set the desired mapping values with the parameters
EthOptMapInp1 ... EthOptMapInp3 and EthOptMapOut1 ...
EthOptMapOut3.
LXM32M
5 Commissioning
Modbus-TCP module
47
0198441113843, V1.01, 01.2012