5.3 Setting the transmission rate
The parameter EthRateSet lets you set the transmission rate.
Set the desired transmission rate with the parameter EthRateSet.
Parameter name
HMI menu
HMI name
Description Unit
Minimum value
Factory setting
Maximum value
Data type
R/W
Persistent
Expert
Parameter address
via fieldbus
EthRateSet Transmission rate setting
0 / Autodetect: Autodetect
1 / 10 Mbps Full: 10 Mbps full duplex
2 / 10 Mbps Half: 10 Mbps half duplex
3 / 100 Mbps Full: 100 Mbps full duplex
4 / 100 Mbps Half: 100 Mbps half duplex
Changed settings become active immedi-
ately.
-
0
0
4
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:2
h
Modbus 17412
Profibus 17412
CIP 168.1.2
5.4 Setting the protocol
The protocol is set by means of the parameter EthMode.
Set the parameter EthMode to "Modbus TCP".
Parameter name
HMI menu
HMI name
Description Unit
Minimum value
Factory setting
Maximum value
Data type
R/W
Persistent
Expert
Parameter address
via fieldbus
EthMode
ConF CoM-
EtMd
Protocol
0 / Modbus TCP / MtCP : Modbus TCP I/O
scanning is enabled
1 / EtherNet/IP / EtiP : EtherNet/IP commu-
nication is enabled
NOTE: Modbus TCP parameter access is
possible irrespective of the selected setting.
Changed settings become active the next
time the product is switched on.
-
0
1
1
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:1
h
Modbus 17410
Profibus 17410
CIP 168.1.1
LXM32M
5 Commissioning
Modbus-TCP module
43
0198441113843, V1.01, 01.2012