5.3 Setting the transmission rate
The parameter EthRateSet lets you set the transmission rate.
▶
Set the desired transmission rate with the parameter EthRateSet.
Parameter name
HMI menu
HMI name
Description Unit
Minimum value
Factory setting
Maximum value
Data type
R/W
Persistent
Expert
Parameter address
via fieldbus
EthRateSet Transmission rate setting
0 / Autodetect: Autodetect
1 / 10 Mbps Full: 10 Mbps full duplex
2 / 10 Mbps Half: 10 Mbps half duplex
3 / 100 Mbps Full: 100 Mbps full duplex
4 / 100 Mbps Half: 100 Mbps half duplex
Changed settings become active immedi-
ately.
-
0
0
4
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:2
h
Modbus 17412
Profibus 17412
CIP 168.1.2
5.4 Setting the protocol
The protocol is set by means of the parameter EthMode.
▶
Set the parameter EthMode to "Modbus TCP".
Parameter name
HMI menu
HMI name
Description Unit
Minimum value
Factory setting
Maximum value
Data type
R/W
Persistent
Expert
Parameter address
via fieldbus
EthMode
ConF → CoM-
EtMd
Protocol
0 / Modbus TCP / MtCP : Modbus TCP I/O
scanning is enabled
1 / EtherNet/IP / EtiP : EtherNet/IP commu-
nication is enabled
NOTE: Modbus TCP parameter access is
possible irrespective of the selected setting.
Changed settings become active the next
time the product is switched on.
-
0
1
1
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:1
h
Modbus 17410
Profibus 17410
CIP 168.1.1
LXM32M
5 Commissioning
Modbus-TCP module
43
0198441113843, V1.01, 01.2012