Parameter name
HMI menu
HMI name
Description Unit
Minimum value
Factory setting
Maximum value
Data type
R/W
Persistent
Expert
Parameter address
via fieldbus
EthIPmodule1
ConF → CoM-
ConF → FSu-
iPc1
IP address Ethernet module, byte 1
Changed settings become active the next
time the product is switched on.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:7
h
Modbus 17422
Profibus 17422
CIP 168.1.7
EthIPmodule2
ConF → CoM-
ConF → FSu-
iPc2
IP address Ethernet module, byte 2
Changed settings become active the next
time the product is switched on.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:8
h
Modbus 17424
Profibus 17424
CIP 168.1.8
EthIPmodule3
ConF → CoM-
ConF → FSu-
iPc3
IP address Ethernet module, byte 3
Changed settings become active the next
time the product is switched on.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:9
h
Modbus 17426
Profibus 17426
CIP 168.1.9
EthIPmodule4
ConF → CoM-
ConF → FSu-
iPc4
IP address Ethernet module, byte 4
Changed settings become active the next
time the product is switched on.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:A
h
Modbus 17428
Profibus 17428
CIP 168.1.10
EthIPmask1
ConF → CoM-
ConF → FSu-
iPM1
IP address subnet mask, byte 1
Changed settings become active the next
time the product is switched on.
-
0
255
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:B
h
Modbus 17430
Profibus 17430
CIP 168.1.11
EthIPmask2
ConF → CoM-
ConF → FSu-
iPM2
IP address subnet mask, byte 2
Changed settings become active the next
time the product is switched on.
-
0
255
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:C
h
Modbus 17432
Profibus 17432
CIP 168.1.12
EthIPmask3
ConF → CoM-
ConF → FSu-
iPM3
IP address subnet mask, byte 3
Changed settings become active the next
time the product is switched on.
-
0
255
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:D
h
Modbus 17434
Profibus 17434
CIP 168.1.13
EthIPmask4
ConF → CoM-
ConF → FSu-
iPM4
IP address subnet mask, byte 4
Changed settings become active the next
time the product is switched on.
-
0
0
255
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:E
h
Modbus 17436
Profibus 17436
CIP 168.1.14
5 Commissioning
LXM32M
40 Modbus-TCP module
0198441113843, V1.01, 01.2012