6.2.6 Operating mode Profile Torque
Starting the operating mode The operating mode is set and started in the process data channel
with the transmit data (master to slave).
dmControl
Bits 0 ... 6
MODE+ACTION
Reference value RefA32 Reference value RefB32
24
h
As PTtq_target As RAMP_tq_slope
Status information The word "driveStat" provides information on the operating mode.
Bit Name Meaning
13 X_ADD1 0: Target torque not reached
1: Target torque reached
14 X_END 0: Operating mode started
1: Operating mode terminated
15 X_ERR 0: No error
1: Error
Terminating the operating mode The operating mode is terminated when the motor is at a standstill and
one of the following conditions is met:
•
Stop caused by "Halt" or "Quick Stop"
•
Stop caused by an error
LXM32M
6 Operation
Modbus-TCP module
59
0198441113843, V1.01, 01.2012