5.2.3 Assignment of the network address via DHCP
EthIpMode has been set to DHCP (dhcp).
Verify that an accessible DHCP server is available on the network.
Set a number that is unique in the network via dhcn.
NOTE: This setting is only required if you want to use an FDR
server.
The number is entered at the 13th, 14th and 15th digit of the
device name.
Example: LEXIUM_SERVO001
In the commissioning software, the full device name can be dis-
played and changed.
Activate the FDR service via EFdr.
See chapter "6.3.3 FDR service (Fast Device Replacement)" for
additional information on the FDR service.
Parameter name
HMI menu
HMI name
Description Unit
Minimum value
Factory setting
Maximum value
Data type
R/W
Persistent
Expert
Parameter address
via fieldbus
EthFdrEnable
ConF CoM-
ConF FSu-
EFdr
FDR service
0 / Off / oFF : FDR service disabled
1 / On / on : FDR service enabled
Enable Ethernet service "Fast Device
Replacement" (FDR).
If FDR is enabled, the DHCP server must
support FDR, otherwise no IP address can
be obtained via DHCP.
-
0
0
1
UINT16
UINT16
UINT16
UINT16
R/W
per.
-
CANopen 3044:40
h
Modbus 17536
Profibus 17536
CIP 168.1.64
5 Commissioning
LXM32M
42
Modbus-TCP module
0198441113843, V1.01, 01.2012