Section 5 Clock Pulse Generator
R01UH0134EJ0400 Rev. 4.00 Page 125 of 2108
Sep 24, 2014
SH7262 Group, SH7264 Group
Table 5.5 CKOEN[1:0] Settings
Setting Normal Operation
Release of Bus
Mastership
Software Standby
Mode Deep Standby Mode
00 Output Output off (Hi-Z) Output off (Hi-Z) Low-level or high-level
output
01 Output Output Low-level output Low-level or high-level
output
10 Output Output Output (unstable
clock output)
Low-level or high-level
output
11 Output off (Hi-Z) Output off (Hi-Z) Output off (Hi-Z) Output off (Hi-Z)
5.5 Changing the Frequency
The frequency of the CPU clock (I) and peripheral clock (P) can be changed by changing the
division rate of divider. The division rate can be changed by software through the frequency
control register (FRQCR).
5.5.1 Changing the Division Ratio
The division rate of divider can be changed by the following operation.
1. In the initial state, IFC1 to IFC0 B'01 or B'10 and PFC2 to PFC0 B'100 or B'011.
2. Set the desired value in the IFC1 to IFC0 and PFC2 to PFC0 bits. The values that can be set
are limited by the clock operating mode and the multiplication rate of PLL circuit. Note that if
the wrong value is set, this LSI will malfunction.
3. After the register bits (IFC1 to IFC0 and PFC2 to PFC0) have been set, the clock is supplied of
the new division ratio.
Note: When executing the SLEEP instruction after the frequency has been changed, be sure to
read the frequency control register (FRQCR) three times before executing the SLEEP
instruction.