Smart Technologies M600i6 Musical Toy Instrument User Manual


 
A P P E N D I X B
Remotelymanagingyour systemthrough anRS-232serialinterface
76 smarttech.com/kb/170549
Field Possible Values Description
current colorwheelidx
???
The ranges must match the OSD ranges.
current failurelog l normal
l overtemp
l fanlock
l fanDMD
l fanblower
l fansystem
l lamperror
l colorwheelbreak
l lampignite
l lampoverheat
l lampdriver
l lampoverhours
Projector's error state. The modes are projector
dependent.
Current error# Provide the details of
the specific error. “#” is
the number recorded in
the log. It ranges from 1
to 5. 1indicates the
most recent error and 5
indicates the oldest
error.
The details include the failure reason, system
hours, lamp hours, sensor temperature and lamp
voltage.
Example: error1=fansystem, syshrs:1000,
lamphrs=1000, temp=60,volt=120.
error2=lampoverheat, syshrs:3000,
lamphrs=2900, temp=150,volt=120.
target factoryreset l = true
l = false
If set to “true,” perform a factory reset.
Otherwise, donothing.
current factoryreset l = true
l = false
Set to “true” only if a factory reset is about to
occur.
target highspeedfan l = high
l = normal
Must match the OSD settings.
current highspeedfan l high
l normal
Must match the OSD settings.
current statereporting l on
l off
Current state reporting value
target statereporting l = on
l = off
Target state reporting value