Honeywell 8650 Building Set User Manual


 
4 - 2
Aiming Modes
There are many aiming “modes” for laser bar code scanners – aiming dots, aiming patterns, aim duration, etc. All aiming
“modes” concern the length of time the beam is sent out, how wide the beam is and what happens when the timer expires. The
terms are used interchangeably and may be confusing for the novice bar code laser scanner user.
Note: Decoding algorithms released by the bar code engine manufacturer often change upon each new release. Programming
parameters that were available at one release may not be available upon a later software release. Honeywell supports
the programming bar codes for the specific engines in this guide only.
SE955 Ring Scanner
The scan engine can have it's aiming beam/aiming dot setup using these bar codes:
Use Laser On Time (page 4-14)
Aim Duration (page 4-7), and
Scan Angle (SE955 only) (page 4-17)
Aiming Dot Help
How to get an aiming dot when there is no “Aiming Dot” parameter:
Set Aim Duration to .5 seconds and an aiming “dot” is sent while the scan trigger is held down. When the timer expires, the
aiming beam widens and the bar code is read.
Prefix / Suffix
Ring decoder engine prefix and suffix parameters should not be set, changed, or reset using the Prefix and Suffix bar codes
shown in this section. When the Bluetooth Ring Scanner module is reset to defaults, the prefix and suffix settings revert to their
default values and need to be scanned again. Use the ScanWedge / ScanWedge NGW Power Tool (Dolphin 70e) or Data
Collection / Scanner control panel (all others) in the host computer to store prefix and suffix values.
Refer to the host user guide (e.g., Thor VM2) for information and instruction on setting up the following scanner parameters:
Enable/Disable decoding sounds
Imager LED Illumination
COM1 Serial Parameters
Code ID: AIM, Symbol, Custom
Symbology Settings including Prefix/Suffix
Control Character Mapping
Custom Identifiers
Pre-Configured Default Values
Ring Scanner Setting 955 Default
Set Default Parameter (page 4-6) All Defaults
Scanning Options
Aim Duration (page 4-7) 0.0 sec
Aiming Mode Not Supported
Beeper Volume Not Supported
Bi-Directional Redundancy (page 4-7) Disable
Laser On Time (page 4-14) 3.0 sec.
Linear Code Type Security Level (Redundancy Level) (page
4-15)
1
Parameter Pass Through (page 4-16) Disable
Parameter Scanning (page 4-16) Enable
Power Mode (page 4-17) Low Power
Raster Expansion Rate Not Supported
Raster Height Not Supported