Length Within Range
This option decodes a code type within a specified minimum and maximum range. For example, when you want to
scan only I 2 of 5 symbols containing between 4 and 12 characters, scan the “I 2 of 5 Length Within Range” bar code
and then “0”, “4”, “1” and “2” bar codes using the Keypad Number Symbols (page 4-72) at the end of this section.
To begin setting lengths within a range, scan this “I 2 of 5 Length Within Range” bar code:
Next, scan numeric bar codes that correspond to the desired value. Single digit numbers must have a leading zero. If
you wish to change your number selection, scan Cancel on the Keypad Number Symbols page.
Any Length
This option decodes I 2 of 5 bar codes containing any number of characters.
Note: Important: Selecting this option may lead to misdecodes for I 2 of 5 codes.
To set any length, scan this “I 2 of 5 Any Length” bar code: