24-Pump, 128-Station Controller Chapter 6: Configurable Settings 70
Name Description Options Default
# pulses Number of pulses of compressed air sent
through the pump’s filter during cleaning.
If blowback is not working as desired, the
service department may ask you to change this
setting.
1–99 5
On time Number of seconds that the air compressor
remains on for each pulse during filter cleaning.
If blowback is not working as desired, the
service department may ask you to change this
setting.
0.1–99.9 sec. 1.0 sec.
Off time Number of seconds between air pulses during
filter cleaning.
If blowback is not working as desired, the
service department may ask you to change this
setting.
0.5–99.9 sec. 1.0 sec.
Implosion with Seal
Valve
When this option is enabled, the controller
builds a vacuum in the filter chamber by
isolating it from the rest of the system with the
sealing valve. The vacuum is then released to
dislodge dust and debris.
Implosion without
Seal Valve
When this option is enabled, the controller
builds a vacuum in the filter chamber by
isolating it from the rest of the system by closing
all the station sequence valves assigned to that
pump. The vacuum is then released to dislodge
dust and debris.
Every n Loads Number of conveying cycles to stations between
filter cleanings.
Adjust this setting based on experience. The
more dust and debris in your material line, the
smaller this number needs to be.
1–99 5
# Pulse(s) Number of pulses of compressed air sent
through the pump’s filter during cleaning.
If blowback is not working as desired, the
service department may ask you to change this
setting.
1–99 5
Vacuum Time Number of seconds allowed for the vacuum to
build up in the filter chamber
Release Time Number of seconds allowed for the vacuum in
the filter chamber to dissipate.