Sterling 882.00255.00 CV3-655 Musical Table User Manual


 
24-Pump, 128-Station Controller Chapter 4: Operation 53
The following table explains the status represented by each color at the Station Status screen.
Color Label Description
Silver Offline Station is not enabled. The controller ignores any demands or
alarms.
Blue Ready Station is enabled and idle (full).
Dark Yellow Demand Station requires material.
Light Green Purging The material line is being purged of material.
Brown Dumping The station is dumping material into its receiver.
White Blow Back Station’s air filter is being cleaned by blowing compressed air
backward through it.
Dark Grey Bypass Bypass switch at the station has been turned on, disabling the
station.
Medium
Green
Priority
Convey
Station is in priority convey mode. Its pump will be temporarily
dedicated to filling it as soon as possible.
Orange Alarm Station is in alarm.
Red Critical Station is in critical alarm. The controller has disabled the station
until the alarm is cleared.
Purple Closed
Loop
Station is in closed loop convey.
Light Yellow Waiting Station is waiting for material to become available.
Dark Green Convey Station is being loaded.
Additional basic information about each station (convey time, dump delay, pump assignment,
and, if enabled, RPV setting, purge settings, etc.) is available at the Station n Operator screen.
See page 56 for details.
Detailed configuration settings for each station are available at the Station n Setup screen. See
page 39 for details.
Reviewing Pump Status
The Pump Status screen is the counterpart of the Station Status screen. To reach the Pump
Status screen from any other screen:
1. Touch Pumps.
The Pump Status screen appears:
The status of each pump is color-coded, as summarized in the upper right of the screen.
You can see a more detailed explanation of each status by using the online help. To do so
from this screen: