Section 25 NAND Flash Memory Controller
R01UH0134EJ0400 Rev. 4.00 Page 1297 of 2108
Sep 24, 2014
SH7262 Group, SH7264 Group
25.3.2 Command Control Register (FLCMDCR)
FLCMDCR is a 32-bit readable/writable register that issues a command in command access mode,
specifies address issue, and specifies source or destination of data transfer. In sector access mode,
FLCMDCR specifies the number of sector transfers.
Bit:
Initial value:
R/W:
Bit:
Initial value:
R/W:
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
151413121110987654321
0
0000000000000000
R/W R/W R/W R/W R/W R/W R/W R/W R R R/W R/W R/W R/W R/W R/W
0000000000000000
R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W R/W
ADR
CNT2
SCTCNT[19:16]
ADR
MD
CDS
RC
DOSR - -
SEL
RW
DOA
DR
ADRCNT[1:0]
DOC
MD2
DOC
MD1
SCTCNT[15:0]
Bit Bit Name
Initial
Value
R/W Description
31 ADRCNT2 0 R Address Issue Byte Count Specification 2
Specifies the number of bytes for the address data to
be issued in address stage. This bit is used together
with ADRCNT[1:0].
0: Issue the address of byte count, specified by
ADRCNT[1:0].
1: Issue 5-byte address. ADRCNT[1:0] should be set
to 00.
30 to 27 SCTCNT
[19:16]
0000 R/W Sector Transfer Count Specification [19:16]
These bits are extended bits of the sector transfer count
specification bits (SCTCNT) 15 to 0.
SCTCNT[19:16] and SCTCNT[15:0] are used together
to operate as SCTCNT[19:0], the 20-bit counter.
26 ADRMD 0 R/W Sector Access Address Specification
This bit is invalid in command access mode. This bit is
valid only in sector access mode.
0: The value of the address register is handled as a
sector address. Use this value usually in sector
access.
1: The value of the address register is output as the
address of flash memory.
Note: Clear this bit to 0 in continuous sector access.