Mitsubishi Electronics MD-CX522-04K to s.7K Building Set User Manual


 
8 PARAMETER FUNCTIONS
8-19
8
Set the bias and gains in Pr. 902 to 905 [Section 8.3.1].
Setting Item
Mode
Instruction
Code
Data Codes and Definitions
Character
count
Write HEC
Bias/gain
Read H6C
H00: Bias/gain
H01: Any analog A/D value
H02: Analog A/D value of terminal
2
MEMO
Once written, the setting of the HEC instruction code is held, but is
cleared to "0" when the drive unit is reset or all clear is performed.
Clear the parameters.
Setting Item
Mode
Instruction
Code
Data Codes and Definitions
Character
count
Parameter
clear
Write HFC
H5A5A: The parameter settings other
than the following are initialized
to the factory settings.
Communication parameters
(Pr. 117 to 124)
Calibration parameter
(Pr. 900 [Section 8.7.5],
Pr. 902, Pr. 903 [Section 8.3.1]
Control parameters
Pr. 75 [Section 8.2],
Pr. 188 [Section 8.4]
Also use the data code H9696 to
initialize the communication parameters.
4
All clear Write HFC
H55AA: The parameter settings other
than the following are initialized
to the factory settings.
Communication parameters
(Pr. 117 to 124)
Pr. 75, Pr. 188
Also use the data code H9966 to
initialize the communication parameters.
4