8 PARAMETER FUNCTIONS
8-5
8
8.4 Selection of the Control Circuit Contact Input Terminal Functions
Pr. 188 "RES terminal operation selection"
Select the reset operation of the RES terminal. Reset operation is performed
when RES-SD are shorted more than 0.1s.
Setting Name Function
0 CPU reset
The cumulative thermal value of the electronic overcurrent
protection stored during operation is initialized. The alarm status
is canceled. Performing reset operation during operation coasts
the motor, and canceling the reset restarts the motor.
1
CPU reset
at alarm
The alarm status is canceled. At this time, the cumulative thermal
value of the electronic overcurrent protection is also initialized.
A reset input is not accepted during normal operation.
MEMO
The reset operation performed using the STOP/RESET key of the
parameter unit will result in an alarm reset regardless of the Pr. 188
setting.
The Pr. 188 setting does not return to the initial value if parameter
clear or all clear is performed.
Pr. 189 "STF, STR terminal operation selection"
You can turn the terminal STF into a start/stop function and the terminal STR into
a direction of rotation direction switching function.
Forward Rotation
Operation
Reverse Rotation
Operation
Stop
Setting
STF STR STF STR STF STR
OFF OFF
0ONOFFOFFON
ON ON
OFF OFF
1 ON OFF ON ON
OFF ON