CM Address Passing
The CM Address Pass setting controls the range of addressed messages that are allowed to pass from
the NCM to the local common module in accordance with the table below. There are four CM Address
Passing settings as follows, Any, = =, > =, and < = .
CM Address Pass Description
1 Any Will pass any messages regardless of the “Local CM Address” setting of the NCM.
Messages without address headers are also passed.
2 = = Will only pass messages with addresses equal to the “Local CM Address” setting of
the NCM
3 > = Will only pass messages with addresses greater than or equal to the “Local CM
Address” setting of the NCM
4 < = Will only pass messages with addresses less than or equal to the “Local CM Address”
setting of the NCM
After all settings are made on the Address page, (Figure 14), click on the Serial Port tab to get to the
Serial Port window as shown in Figure 15.