11 - 34 11 - 34
MELSOFT
11. POSITIONING DEBUGGING
DISPLAY/SETTING DATA
Item Description
Speed limit
Shows the speed limit value set to the basic parameters 2.
Refer to Section 8.1.2 for the setting of the basic parameters 2.
Correcting speed
Set a new speed to the command speed, OPR speed or JOG speed in the positioning data
of the axis being operated.
"#1 Speed req." button
"#2 Speed req." button
"#3 Speed req." button
Click any button to change to the value set to Correcting speed.
Speed dump
Set the multiplying factor (%) of the speed overriding the command speed, OPR speed or
JOG speed in the positioning data.
The override value once executed is valid during the test mode.
The setting range is 1 to 300%.
"#1 dump req." button
"#2 dump req." button
"#3 dump req." button
Click any button to write the override value to the AD75 and change the command speed,
OPR speed or JOG speed in the positioning data to the speed multiplied (%) by the value set
to Speed dump.
Executing this function in the standby status reflects the speed from the next operation.
The speed is also changed when this function is executed for the axis being operated.
"#1 stop" button
"#2 stop" button
"#3 stop" button
Click the corresponding button to stop the axis on which the positioning start test is being
made.
Reset the error after a stop since the axis results in an error occurrence status.
"All stop" button
Click this button to stop all operating axes.
Reset the error after a stop since the axis results in an error occurrence status.
"Error reset" button
(
/
/ )
Click any button to reset the error of the corresponding axis.
"M code Off" button
(
/
/ )
Click any button to turn off the M code ON signal (XD, XE, XF) of the corresponding axis.